Environmental Conditioning and Aerosol Infection of Mice
Author:
Date:
2020-04-20
[Abstract]  Influenza infection models in mice are widely used to study flu-mediated immune responses and pathology. However, most laboratory mice are housed at 20 °C and 50% relative humidity (RH). To better recapitulate influenza epidemics and immune responses during winter seasons, mice were housed at 20 °C under different humidity conditions, 10-20% or 50% RH. Here, we describe a protocol for using aerosolized droplets to infect mice with influenza under different environmental conditions. Using this method enables influenza infection studies performed under more physiologically relevant conditions which better mimics human viral exposure.
[摘要]  [摘要 ] 小鼠的流感感染模型被广泛用于研究流感介导的免疫反应和病理学。然而,大多数实验室小鼠被安置在20 °C 和50%相对湿度(RH)的条件下,以更好地概括流感流行和免疫应答。在冬季,将小鼠饲养在20 °C,不同湿度条件下,相对湿度10-20%或50%的环境中,在此,我们描述了一种在不同环境条件下使用雾化液滴感染小鼠的方案。在生理上更相关的条件下进行的研究,可以更好地模拟人的病毒暴露。

[背景 ] 甲型流感病毒(I AVs)是世界上季节性呼吸道感染的主要原因之一,每年导致50万人死亡(Johnson 等,2014)。冬季温带地区爆发IAV ,高峰十一月至三月在北半球之间五月至九月在南半球之间(Tamerius 等,2013;阿隆索等人,2015年)。病毒学研究的豚鼠表明,低温低湿实现了更好的空气传播流感病毒(洛文等,2007) 。此外,流行病学研究表明,一滴水在绝对湿度相关因素密切配合上升,流感相关的死亡在人类(萨满等,2010) 。值得注意的是,在热带在潮湿和温暖的亚热带气候区,病毒可以在物体表面繁殖并引起细小病毒传播(Shek和Lee ,2003;Moura 等,2009)。

实验室小鼠一般维持在宏观环境的温度和相对湿度范围为64〜79°F(17.8到26.1°C)和30 Pasento为70 ...